Check that unit is correctly wired for 240 VAC and connected to 240 VAC. Remove and clean flow/temp/salinity sensor and reinstall. . Dedicated support Call us Mon - Fri, 8AM - 5PM (PST) 1-800-822-7933 Email us Mon - Fri, 8AM - 5PM (PST) productsupport@fluidra.com Product Registration To ensure the best customer service and tracking, register your product. Not replaceable. That made a little sense to me based on some things I was seeing. Then check the prongs. They are built of a rugged glass-filled polypropelene material, have standard Jandy unions, and are NSF listed for your commercial application. . Also referred to as a repair manual or service manual. #1 Hi, I'm on my 3rd Jandy flow sensor in 3 years. Additional Information AquaPure System Brochure Zodiac Salt Sanitizing Brochure Aquapure Installation and Owners Manual AquaPure and Purelink Tri-Sensor Replacement Kits AquaPure Powerpack For Purelink cell kits (APUREM) Apple is not a participant or sponsor of this promotion. You can get a new cell and replace the power supply if it fails or you can just get a whole new system. 0000000816 00000 n
This manual contains important information about the installation, operation and safe use of this product. Hello , This is an inactive thread. SWG hasn't been generating chlorine for a while. . Our heavy-duty AquaPure salt chlorine generators have been the industry benchmark for years.
Chlorine generating device, aquapure ei series (96 pages) Water Filtration Systems . Hopefully all will hold. If not, clear the memory. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Manually shock the pool following the directions in Section 5.4.1 of the owner's manual, Shocking. Remove obstruction and/or clean cell. Description AquaPure Ei Series I/O Manual. Troubleshooting Jandy AquaPure Error Codes - The Pool Life I think I found the problem. Zodiac Pool Systems AQUAPURE Ei Technical Training Manual Troubleshooting Data Troubleshooting Manual WARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/ spa service technician. Safety Information 4 Save These Instructions 5 Section 2. It wasn't generating before and new salt cell just kicked off more errors. Here at INYO Pools we come across this situation a lot. PDF AquaPure Series - INYOPools.com check out the. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. Jandy AquaPure PureLink 3-Port Salt Cell Kit 3-Port cell has 90 plumbing flexibility, durable housing, sensor integrated into third port and larger unions for easy installation Solid titanium plates manufactured with multiple coatings of precious metals to provide efficient chlorine production and enhanced cell life Release the OUTPUT button. Please consider. See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. Pool Life is committed to building the most spectacular swimming pools in Greenville and the Upstate. So convert your ordinary chlorine pool into a salt water oasis today. Yes, I know they usually don't last beyond 3-4 years but please read on. %%EOF
Then adjust pH to within the range 7.4-7.6. Opened pool 2 weeks ago. 188. Below youll find a complete []. Jandy Salt System Not generating Chlorine - DoItYourself.com Hopefully when all is in balance, I'll notice that the SWG is working as it should. The AquaPure Ei delivers the ultimate swimming experience without the hassle. Page 15 Operation Salt Ocean water - 36,000 PPM Tear drop - 7,200 PPM AquaPure Ei - 3,500 to 4,000 PPM As a general guideline the purer the salt, the better the life and performance of the chlorinator. JavaScript is disabled. (Generates 173 - Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional. Front board power supply either too low or too high. My sensor module is set to Program B based on the firmware on my AquaPure. Salt Water Sanitation System: Jandy AquaPure Ei | Jandy I have the jumper on (I actually did this by soldering it after troubleshooting another time). Add stabilizer to maintain 50 - 75 PPM per pool professionals recommendations. Specifications *Pool sizes are generalizations and may vary with environmental conditions. By Pahonex in forum Salt Generators (SWCG) & other Chlorine Feeders, By ulaoulao in forum Pool Equipment & Operations, By StoshJ in forum Salt Generators (SWCG) & other Chlorine Feeders, By trauh in forum Salt Generators (SWCG) & other Chlorine Feeders, By dsikes in forum Salt Generators (SWCG) & other Chlorine Feeders, Salt Generators (SWCG) & other Chlorine Feeders, Pool Water: Treatment, Testing & Problems (P), http://www.pleasurepoolsno.com/manuag%20Manual.pdf, Testing and Adjusting Pool Water Chemistry, Using Chlorine and Chlorinating Chemicals. (Cycle Power). Check for correct operation of the pump. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. Register Product Warranty Policy 0000002316 00000 n
ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. See Section 6.3, Step 2 of the owner's manual. Buyer's Guide; Buyer's Guide. The controller setting will appear on the display. Introducing the worlds first DIY Salt Water Purification System: the AquaPure Ei, a compact, self-contained system. Aquapure Jandy Salt Sensor Issue | Trouble Free Pool 2023 Zodiac Pool Systems LLC - All rights reserved. In addition to a Sensor Flow Indicator, there are Program A and Program B indicators. 0000006542 00000 n
PureLink Cell Kits 3-Port cell has 90 plumbing flexibility, durable housing, sensor integrated into third port and larger unions for easy installation Solid titanium plates manufactured with multiple coatings of precious metals to provide efficient chlorine production and enhanced cell life 234 26
To keep these units running at top efficiency, the digital controls will display a code when something needs service. AquaPure and PureLink Troubleshooting Manual | PDF | Power - Scribd Zodiac -Jandy Pro Series PLC1400, 3-PORT CELL, CHLORINATOR CELL KIT Apple is not a participant or sponsor of this promotion. You need a Jandy aqua pure 1400 troubleshooting guide? Suggestions? While still pressing the test button, press the 'Salinity' key ('C') together with the 'Chlorine Production Rate' arrow down key ('A') on the front cover of the unit. Plug in flow/temp/salinity sensor. Jandy Pro Series AquaPure Power Pack AquaPure Salt Chlorinator Models Sanitizer Type Body Material Chlorine Connections Input Current Output Pool Size Recommended Flow Rate Maximum Pressure Recommended Tablets Chamber Capacity of Chlorine Code 194 means that the current going to the cell is too low. Rely on its sturdy design and simple features to create your saltwater oasis. Jandy Aquapure Troubleshooting Guide - Pool Forum Salt Chlorinator: Jandy AquaPure | Jandy Find a Dealer AquaPure Salt Water Pool System Downloads Document ID SL6605 Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used. 2023 Zodiac Pool Systems LLC - All rights reserved. Increase chlorine production by pressing the Chlorine Production Rate Adjustment button (arrow button B). The display on the unit is showing as 3.9gpl and app shows the same 3900 PPM. Do not Add Salt through Skimmer, Main Drain or Surge Tank. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Jandy AquaPure Manuals & User Guides Look closely and you will see two small screws holding the cover plate down over the prongs. The prongs go through the cell housing and are partially secured by a cover plate that compresses O-rings on each prong. Read some stuff here that made me think I need to re-add the mini-board that I took off when I got the new salt cell and it came with the Sensor Indicator Module. The default is set to Jandy L/M. Recheck. and 'Minerals' & 'Ions', Chlorine Alternatives: UV, Ozone, Baquacil (PHMB), etc, Pool Construction, Equipment, Operations, Seasonal Care (P), Pool Startup, Shutdown, & Winter Operation, Jandy PureLink/AquaLink RS/AquaPure Problem, If this is your first visit, be sure to
0000004048 00000 n
Now I'm getting Error 125 and 194. 0000003316 00000 n
Database contains 3 Jandy AquaPure Manuals (available for free online viewing or downloading in PDF): Installation and operation manual, Workbook . . 0000009525 00000 n
Salt test strip says 3200ppm. I have a Jandy APURE35 and getting the code TEST CELL. There And since it purifies automatically, youll spend less time worrying about your pool and more time enjoying it. ev-; We are a registered 501(c)3 non-profit that is funded by user donations. Dilute pool with fresh water. Troubleshooting Help Hard Reset The Ei has a 'hidden HARD RESET button located to the right of the Jandy logo, that can be used to reset the microcontroller. System Description 6 Electrical Speci Cations 7 Section 3. In about 15 minutes you can have soft, silky water, free of the annoying and harmful effects of conventional chlorine. Ei to Goldline Adapter Fitting Install Instructions. Rely on its sturdy design and simple features to create your saltwater oasis. and the problem is with the sensor.
7?q~gh}SY4_RXS.gV. Our team of award-winning designers will answer all of your questions, and work with you to design the backyard of your dreams. Broadcast or Spread Salt into Shallow End of Pool. #1 Hi all, I was having an issue with my salt cell sensor giving me erroneous salt readings and eventually not detecting flow. For a better experience, please enable JavaScript in your browser before proceeding. See Section 2, Figures 2a, 2b, and 2c of the owner's manual. Jandy AquaPure Manuals & User Guides User Manuals, Guides and Specifications for your Jandy AquaPure Lighting Equipment, Water Filtration Systems. See Section 6 of the owner's manual, User Maintenance Instructions. 234 0 obj <>
endobj
See Section 4.5 of the owner's manual. Increase the system operating time per day. Follow cleaning procedures. Super Chlorinate Pool. This could be a defective automatic timer or pump switch or loose connection at the automatic timer or pump switch. %PDF-1.4
%
Troubleshooting Jandy AquaPure Error Codes - Leslie's Pool Supplies #1 Last year, I was having problems generating chlorine with my Jandy salt water system, and I cleaned the cells but still had a problem generating chlorine. Directions for Adding Salt: Boost - 24 Hour 100% Chlorine Production Cycle - Refer to Manual - Posted July 3, 2009. No Flow And Cell Reversing On Jandy Aquapure 1400 If not, contact a pool professional. Ensure there is no loss of pump prime or clogged strainer baskets. With that in mind, we wanted to create an easier way for homeowners to diagnose their Jandy AquaPure. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. (Generates 173 code if Level II code 187 is present) Contact a pool professional. AquaPure service codes identify the problem and direct you to an available solution. Any new postings here are unlikely to be seen or responded to by other members. Drop in the Best When You Replace the Rest. Jandy AquaPure Electronic Chlorine Generator APURE700 and APURE1400 Installation and Operation Manual WARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/spa service technician. Continue holding the OUTPUT button until the desired controller setting is displayed on the screen. Plug flow/temp/salinity sensor into connector on power center printed circuit board. 78 May 31, 2020 #1 I'm really hoping to find a solution to have this SWG last one more season because my budget is very tight with this whole pandemic situation. RRRRRRRR, Do not sell or share my personal information. NOTE: To clean the deposit (scale) on the electrolytic cell plates, see Section 6.3 of the owner's manual. 0000009699 00000 n
Hi can you tell me if a Jandy aqua pure EI series Apure35 MFG 07.2010 is a current model or a discontinued model Serial . Consult your pool professional regarding use of a sequestering agent. Pools with greater exposure to sunlight may require greater chlorine production capacity. AquaPure Ei | Jandy For example, serial number CM3 01 06 13 86 can be read as follows: CM3 0000004708 00000 n
Verify salinity with Myron L meter calibrated for NaCl, titration test units, or other salt meters. AquaPure Guide d'installation et mode d'emploi.